Home
 
 








Fisher Controls International


Domestic

First Stage Regulators
First-stage Regulators reduce tank pressure to a lower pressure (usually 10 psig) for a second-stage regulator. Fisher First-Stage Regulators are painted red for easy identification. Vents are screened with standard orientation over outlet.

2 PSIG Regulators

2-PSI Service Regulators are designed for 2-PSI LP-Gas regulator systems. They are installed downstream from a first-stage regulator and reduce an inlet pressure of 10 PSIG to a nominal 2 PSIG outlet pressure. 2-PSI Service Regulators are designed for domestic applications that supply LP-Gas through corrugated stainless steel tubing to a line regulator located inside the building. Fisher 2-PSI Service Regulators are powder-coat painted white for easy identification.

Second Stage Regulators
Second-Stage Regulators Reduce the pressure from a first-stage unit to 11-inch water column in domestic installations. Vents are screened with standard orientation over inlet and other vent orientations available. Fisher Second-Stage regulators are normally painted palm green for easy identification.

Integral Two Stage Regulators

Integral Two-Stage Units combine a First-Stage Regulator and Second-Stage Regulator into one compact unit. Recommended for installations where piping distance is short, integral two-stage regulators provide all the advantages of two-stage regulation.

Fisher Integral Two-Stage Regulators are color coded gray for easy identification. Vents are screened with standard second-stage orientation over outlet.


Commercial/Industrial Regulators
For large loads such as factories, office buildings, restaurants, etc., Fisher has a variety of commercial/industrial regulators. The higher capacities on commercial and industrial installations typically require a two-stage regulator system.

High Pressure Regulators

High Pressure Regulators (pounds to pounds) typically reduce tank pressure to an intermediate pressure for use by another regulator. They may be used as high pressure regulators on distribution systems in conjunction with a first-stage downstream regulator.

They are also used for final stage service on high pressure burners in crop dryers and tobacco curers, as well as other medium sized commercial/industrial applications.
Marshall Gas Control Regulators

Low Pressure Single Stage Regulators
Marshall Low Pressure Regulators are available with a drip lip vent configuration. They are approved for use on small portable appliances or outdoor cooking appliances that utilize low pressure.

Low Pressure Two Stage Regulators
The Marshall Two-Stage Changeover Regulator offers the convenience of changeover, switching from gas cylinders to full gas cylinders. The top portion of the the changeover is a dual high pressure regulator, which reduces container pressure to approximately 10 to 15 PSIG and sends it to the second stage regulator. The second stage regulator then completes the regulation process, reducing the inlet pressure to 11 inches of water column outlet pressure.

Single Stage 90 Degree Regulator
The Single Stage 90 Degree Regulator's size, shape and flow characteristics make them ideal for use on propane appliances that require 100,000 BTU or less. A variety of connection options are also available.

Adjustable High Pressure Regulator
The Marshall Adjustable High Pressure Single-Stage Regulator is designed for use with appliances that require pounds per square inch of pressure instead of WC inches. The improved knob design assures quality service and positive valve closure.

Return to Products



Copyright ©2007 Bergquist, Inc. All rights reserved.
| 5 Locations | Manufacturers | Products | About Bergquist | Contact Us |